All installations and services must be performed by qualified service personnel.

: The vent and air intake elbows must be kept away from bushes, shrubs or any vegetation that may restrict the flow of flue products. It must also be kept clear of any leaves, weeds or other combustible materials. Keep the vent hood clear of snow. Avoid locating the terminals in areas where standing water or condensate drippage may be a problem.

: This CMA/CMC furnace has been designed to be installed as a direct vent system and must have its combustion air brought in from outside the conditioned space. The failure to install the vent/air intake system as specified in these instructions will void the heat exchanger warranty and may result in property damage, personal injury or loss of life.

: Outside combustion air must not come from an area that is directly adjacent to a pool, hot tub or spa. Measures should be taken to prevent the entry of corrosive chemicals or vapors to the combustion and ventilation air supply. Such chemicals include but are not limited to chlorinated and/or fluorinated hydrocarbons such as found in refrigerants, aerosol propellants, dry cleaning fluids, degreasers and removers. Other harmful compounds may come from bleaches, air fresheners or mastics. Vapors from such products can form acid compounds when burned in a gas flame. Should acid compounds form in your furnace, it may reduce the life of the furnace.

: Because of the potential of odorant fade, a gas leak may not be detected by smell. If this furnace is installed below grade, contact your gas supplier for a gas detector.

: All gas piping must be leak tested methods approved by State, Local and National Codes including the National Fuel Gas Code NFPA 54/ANSI-Z233.1 (Latest Edition). A final test for gas leakage must be made after purging the gas line. This test must be conducted with the unit operating and should include the furnace piping and gas valve. Never use an open flame to check for a gas leak.

: Care must be taken not to wet electronic components during leak test. Wetting the primary ignition module may damage its circuitry and cause a hazardous situation. Dry moisture from all leads and terminals if wetting occurs. Wait at least 24 hours for the circuit to fully dry before energizing the burner circuit.

: The furnace and its individual gas shutoff valve must be disconnected from the gas supply during pressure testing of the gas supply system at pressures in excess of 1/2 PSIG or 14.0" w.c. The furnace must be isolated from the gas supply by closing its manual shut off valve at test pressures equal to or greater than 1/2 PSIG or 14.0" w.c.

5

Page 7
Image 7
Thermo Products CMC1-50D36N, CMC1-50DV3N, CMC1-75D36N, CMA3-50D36N, CMA3-75D36N, CMC1-75DV3N service manual

CMC1-75DV3N, CMA3-75D36N, CMA3-50D36N, CMC1-75D36N, CMC1-50D36N specifications

Thermo Products offers a versatile range of heating solutions that cater to various industrial and commercial applications. Among their popular models are the CMC1-75DV3N, CMC1-50DV3N, CMA3-50D36N, CMC1-50D36N, and CMC1-75D36N. Each model is engineered to deliver efficient performance and durability, making them ideal for meeting diverse heating needs.

The CMC1-75DV3N is tailored for high-capacity heating requirements, featuring advanced heating technology that ensures rapid and consistent heating. Its robust design includes high-efficiency burners, and the unit is built with durable materials for extended lifespan. This model is equipped with integrated safety mechanisms that prevent overheating and ensure reliable operation.

In contrast, the CMC1-50DV3N is designed for medium-sized applications, prioritizing both efficiency and cost-effectiveness. It includes automated controls to optimize energy usage while maintaining consistent temperature outputs. Its compact footprint makes it suitable for installations with space constraints, without compromising on heating performance.

The CMA3-50D36N model introduces enhanced energy management features, offering dynamic heating solutions. This model leverages advanced thermal technologies that aim to reduce energy consumption while maximizing heating output. Its versatile installation options allow users to adapt the unit to their specific space requirements seamlessly.

The CMC1-50D36N and CMC1-75D36N models are recognized for their adaptability across various applications. The CMC1-50D36N specifically caters to smaller heating needs, while the CMC1-75D36N serves larger spaces. Both units come equipped with user-friendly interfaces that simplify operation and adjustments, allowing for precise temperature control.

All models feature high-quality insulation and construction, helping to minimize heat loss and enhance system efficiency. They are designed with maintenance in mind, ensuring easier access to key components for service and repairs.

Through the incorporation of customizable settings, these models can suit the unique requirements of different environments, whether it be industrial facilities, commercial spaces, or residential buildings. With Thermo Products' commitment to innovation and quality, these heating solutions exemplify reliability, making them a solid choice for anyone in need of efficient heating technology.