Chapter 2: Component Descriptions

Table 7: LCD Panel Menu Options for the EX8200 Switch (continued)

Menu Description

Maintenance The Maintenance menu has the following options:

SYSTEM HALT?—Choose one of the following:

Press Enter to halt the master SRE module in an EX8208 switch or to halt the master RE module in an EX8216 switch. Press Enter again to confirm the halt.

In a base configuration switch, the master SRE or RE module will be gracefully halted but not powered off. Press Enter on your management device or power cycle the switch to bring the switch back up.

In a redundant configuration, the backup SRE or RE module takes over mastership when the master SRE or RE module is halted. To completely halt the switch, use the request system halt other-routing-engineCLI command to halt the backup SRE or RE module before halting the master SRE or RE module. Press Enter on your management device or power cycle the switch to bring the switch back up.

See “EX8208 Switch Configurations” on page 6 or EX8216 Switch Configurations for information on configuration types.

Press Menu to go to the next option in the Maintenance menu.

SYSTEM REBOOT?—Choose one of the following:

Press Enter to reboot the master SRE or RE module. Press Enter again to confirm the reboot.

Press Menu to go to the next option in the Maintenance menu.

LOAD RESCUE?—Choose one of the following:

Press Enter to roll back the switch to the previous valid configuration. Press Enter again to confirm the rollback.

Press Menu to go to the next option in the Maintenance menu.

FACTORY DEFAULT?—Choose one of the following:

Press Enter to restore the switch to the factory default configuration. Press Enter again to confirm the restoration. The LCD flashes a success or failure message and returns to the Idle menu.

Press Menu to go to the next option in the Maintenance menu.

ENTER EZSETUP?—Choose one of the following:

Press Enter to launch EZSetup. Press Enter again to confirm the launch.

EZSetup configures DHCP and enables the J-Web user interface on the switch. The LCD flashes a success or failure message for approximately 10 seconds and returns to the Idle menu.

Press Menu to go to the next option in the Maintenance menu.

NOTE: You can use the EZSetup option only if the switch is in the factory default configuration.

EXIT MAINT MENU?—Choose one of the following:

Press Enter to exit the Maintenance menu.

Press Menu to return to the SYSTEM HALT option.

If you do not want users to use Maintenance menu options, disable the entire menu or individual menu options. See Configuring the LCD Panel on EX Series Switches (CLI Procedure).

You can view the information about the LCD panel in EX8200 switches by executing the command show chassis hardware. It shows the version, part number, serial number, and description of the LCD panel.

Related Topics Chassis Status LEDs in an EX8200 Switch on page 22

Field-Replaceable Units in an EX8208 Switch on page 23

Field-Replaceable Units in an EX8216 Switch

Copyright © 2010, Juniper Networks, Inc.

21

Page 47
Image 47
Juniper Networks EX8208 manual LCD Panel Menu Options for the EX8200 Switch