Chapter 1: EX8208 Switch Overview

Table 4: Switch Fabric Redundancy for EX8208 Switches (continued)

 

 

 

 

Switch Fabric

Switch Configuration

Slot SRE0

Slot SRE1

Slot SF

Redundancy

Base configuration

Empty

SRE module

SF module

No

User-defined

SRE module

SRE module

Empty

No

configuration

 

 

 

 

Redundant

SRE module

SRE module

SF module

Yes

configuration

 

 

 

 

Related Topics

Switch Fabric and Routing Engine (SRE) Module in an EX8208 Switch on page 24

Switch Fabric (SF) Module in an EX8208 Switch on page 28

Slot Numbering for an EX8208 Switch

An EX8208 chassis accepts eight line cards, two Switch Fabric and Routing Engine (SRE) modules, one Switch Fabric (SF) module, one fan tray, and six power supplies (AC or DC). All 11 slots for the line cards and the modules run horizontally across the front of the chassis. The fan tray slot runs vertically on the left of the chassis front. The six power supply slots run vertically across the front bottom of the chassis.

This topic describes:

Slot Numbering for SRE and SF Module Slots and Line Card Slots on page 13

Slot Numbering for the Power Supply Slots on page 15

Slot Numbering for SRE and SF Module Slots and Line Card Slots

Table 5 on page 13 lists the slot numbers on the EX8208 chassis and the components those slots accept.

Table 5: Slot Numbering for an EX8208 Switch

Slot Label

Components Accepted in Slot

0

Line card

1

Line card

2

Line card

3

Line card

SRE0

SRE module

SF

SF module

SRE1

SRE module

Copyright © 2010, Juniper Networks, Inc.

13

Page 39
Image 39
Juniper Networks manual Slot Numbering for an EX8208 Switch, Slot Label Components Accepted in Slot, SRE0, SRE1