Controls and Features (cont.)

Control Panel (Cont.)

1

2

3

4

5

6

7 8

STAND BY

 

 

VIC SELECT

 

MENU

T

+

 

 

 

 

 

 

 

 

 

 

1

 

 

 

 

OPERATE

HIDE

 

 

 

 

 

 

 

 

KEY STONE 2

 

 

ZOOM

FOCUS

 

 

 

3

 

 

 

 

 

 

 

 

EXIT

ENTER

W

9 p q

 

 

 

w

e

 

 

qSTAND BY Indicator

On : When in stand-by mode.

Blinking : While in cool-down mode.

CAUTIONS

The cool-down mode continues for about 10 minutes. At the first 20 seconds of the cool-down mode, the projection cannot be started again. During this period, the STAND BY indicator is blinking and “07” appear on the status code display.

Then, “07” changes into “06” on the status code display, but the STAND BY indicator is still blinking, and the cooling fans will continue to run for about 10 minutes before they stop.

After the cooling-down mode, the projector goes into stand-by mode automatically (the STAND BY indicator is not blinking but lit).

The purpose of the cool-down mode is to prevent inner parts from being deformed or broken by heat from the heated lamp as well as to prolong the life of the lamp.

Do not turn off the MAIN POWER switch while in the cool-down mode. Also, do not block any of exhaust openings while in cool- down mode.

The cooling fan for the light-source lamp power supply continues running as long as the MAIN POWER switch is turned on.

wEXIT button

Use this button in the menu mode to return to the previous menu. When the main menu is displayed, this button will cause the menu to disappear.

For details on the operations, refer to page 42.

eENTER button

Use this button in the menu mode. Use it to display the hierarchical menus. Also use it when “ENTER” is displayed for the item on the menu.

For details on the operations, refer to pages 16 and 42.

About status code

Normal indications

Code

Status

00The projector is in stand-by mode.

01The projector is in normal status.

06The projector is in the cool-down mode. (enable to start the projection again)

07

The projector is in the cool-down mode.

 

 

Error indications

Code

Status

 

 

02

The side panel is unstable.

 

Abnormal temperature in the lamp unit.

 

The lamp cannot light up.

 

 

03

The internal shutter is closed or there may

 

be trouble in the shutter function.

 

 

04

The projector is turned off while no signal is

 

input.

 

 

10

The lamp goes off during projection.

 

 

20

Trouble in the light-source lamp power

 

supply.

 

 

21

Trouble in the power supply of the projector.

 

 

22

Trouble in the power supply of the fan.

 

 

23

Trouble in cooling process of R-device.

 

 

24

Trouble in cooling process of G-device.

 

 

25

Trouble in cooling process of B-device.

 

 

30

Trouble in the fan or the sensor of air

 

pressure.

 

 

40

Trouble in the micro processor.

 

 

80

The lamp life is near its end (exceed 900

 

hours).

 

 

81

The lamp life is near its end (exceed 1000

 

hours).

 

 

82

Abnormal temperature in the projector.

 

 

83

Abnormal temperature in the room.

 

 

ENGLISH

11

Page 13
Image 13
JVC DLA-QX1G manual About status code