Menu Configuration (cont.)
Scope Setting*1
Configure the settings for the wave form monitor and vector scope.
Item | To do |
|
|
| Setting value |
Gain*2 | Adjust the input gain level. |
| |||
Size*3 | Set the window size. |
| Normal, Large | ||
Position | Select the window position. |
| Lower Right, Lower Left | ||
|
|
|
|
| Upper Left, Upper Right |
Transparent | Activates/deactivates the function to make the window translucent. |
| Off | ||
| Off | : | Normal |
| On |
|
|
| |||
| On | : | Translucent |
|
|
Auto Off | Set the function to turn off the window automatically 15 minutes after displayed. |
| Off, On | ||
Histogram Display | Select the signal component for the histogram display. |
| Y, R, G, B, RGB*4 | ||
Wave Display | Select a wave form to be displayed for the wave form monitor. |
| Y, Pb, Pr (HD signal) | ||
|
|
|
|
| Y, Cb, Cr (SD signal) |
|
|
|
|
| R, G, B (RGB signal) |
Wave Filter | Turn on/off the lowpass filter to put over the input wave form data. |
| Flat (No filter) | ||
|
|
|
|
| Lowpass |
|
|
| |||
Wave Over Level Marking | Turn on/off the function to change the wave form color of signals over the value specified in | Off, On | |||
| “Wave Over Level”. (☞ below) |
|
| ||
Wave Over Level | Adjust the lower limit for the over level. |
| 70 – 109 | ||
<Example of the histogram | display> |
| <Example of the wave form monitor> | <Example of the vector scope> |
Pixels
< dark | brightness | light > |
The start and the end of the gradient correspond to 0% and 100% of the signal.
RedWhite
Y
Image signals
Start | End |
Ex.: When the luminance signal is Y, “Wave Over Level Marking” is set to “On” and “Wave Over Level” is set to “80”
Ex.: When the color bar is displayed
| • The wave form color of signals over the value |
| specified in “Wave Over Level” turns red. |
| • The display differs depending on the input |
| signal or the “Wave Display” setting. |
*1 | The vector scope is not displayed when the input signals are RGB. |
*2 | Unavailable for the histogram. |
*3 | Only “Normal” is available for the histogram. |
*4 |
Sync Function
Settings for the synchronization with signals.
Item | To do | Setting value |
No Sync Action | Select the screen status when no signal is coming in. | Off, Standby, Power Save |
|
| (power save mode), |
|
| Gray Back (gray screen) |
Delay Time | Select the period until the screen status changes as selected in “No Sync Action” after signals | 30s, 5min, 15min |
| stop coming in. |
|
Low Latency | Activates/deactivates the function to shorten the time taken to display the picture (low | Off, On |
| latency function). |
|
| • If the picture is not displayed steadily while “On” is selected, select “Off.” |
|
| • While “On” is selected, the displayed picture may become unstable when an operation |
|
| using buttons on the front panel or the menu is performed, or when the signal format |
|
| changes. |
|
●When setting “No Sync Action” to “Gray Back,” the screen color changes to gray and the power consumption of the backlight is saved by half. Selecting “Power Save” (power save mode) saves more power consumption by turning off the backlight.