Mounting the Lens

Follow the procedures below when mounting the auto iris lens. Refer to the ‘instruction manual’ for the lens as well.

English

Camera Head

2. Lock

Threaded

Portion(Male)

Mount Fastening Ring

Lens

1.

Compatible Zoom Lens

T14 x 5.5MD

Caution

Perform this when the unit is off. Connecting with the power on may give rise to malfunction of the unit.

When removing the lens mount cap, ensure that no foreign substances are inside the mount.

Lenses are not supplied with this unit. Depending on the lens being used, this unit may be damaged. As such, ensure to use lens that are 4 mm or be- low, reference from the lens mount.

4 mm and below

1. Align and press the threaded portion of the lens mount against the threaded portion of this unit’s lens mount and turn the mount fastening ring clockwise slowly until the lens is firmly attached to this unit.

Note

To change the position of the lens rotation,

1First, loosen the mount fastening ring by rotat- ing it anti-clockwise by 1/4 turn as viewed from the lens side.

2Turn the lens gently, adjust the position and tighten the mount fastening ring again.

2. Plug the lens cable into the [LENS] terminal at the back of the unit and ensure that it is locked. Iris control is carried out from this unit.

Setting the “IRIS MODE” of the “EXPOSURE” Screen

Page 33

If auto iris lens is to be used and iris control is to be automatically carried out, set to “AUTO”.

If auto iris lens is to be used and iris control is to be fine-tuned, set to “MANUAL”.

E-17

Page 17
Image 17
JVC KY-F550E instruction manual Mounting the Lens