16
INSTALLATION
Control signal cables
These cables should be connected only
when it is required to control the cam-
era using the RS-442A or RS-485 sig-
nals. The use of 0.65 4-conductor
twisted pair cables is recommended.
With these cables, the maximum exten-
sion distance is 1,200 m.
After having connected all of the re-
quired cables, again attach the termi-
nal board cover.
Forgetting to attach the terminal board
cover could result in accidents or
injuries.
6mm
12mm
Meshed wire Polyethylene
Fold the meshed wire back.
Core
conductor
Video signal cables
Connect the coaxial cables to the video
signal output terminals. Treat the tips of
the coaxial cables as shown on the left
before connection.
Note
Use the 3C-2V or 5C-2V video signal
cable (coaxial cable). The 7C-2V
cannot be used.
Connect to the
other side in
pairs like this.

A TX+

B TX-

C RX+

D RX-

Connect to the
other side in
pairs like this.
Connections to Camera Terminal Board (Continued)