31
Only displayed when making settings by sending commands from an external controller,
such as the RM-P2580.
Item Function Variable Factory
range setting
POSITION
TEXT EDIT
POSI. TEXT
LOC.
AUTO
PATROL
AUTO PAN
MODE
ALM. TEXT
SIZE
END
UP-L
DOWN-L
UP-C
DOWN-C
UP-R
DOWN-R
PAN
TILT
SCROLL
NORMAL
DOUBLE
UP-L
PAN
DOUBLE
When the SET button is pressed, the POSI-
TION TEXT setting screen is displayed. Up to
16 characters can be used as titles for set po-
sitions and home positions.
See page 39.
Selects the position for displaying POSITION
TEXT on the screen.
UP-L: Upper left side DOWN-L: Lower left side
UP-C: Upper center DOWN -C: Lower center
UP-R: Upper right side DOWN-R: Lower right side
Used to set the position order and the surveil-
lance time for Auto Patrol operation.
When the SET button is pressed, the AUTO PA-
TROL setting screen appears.
See page 41.
Selects the operation mode when the AUTO
PAN command is received. (In the case of RM-
P2580, this selects the operation mode when
the AUTO PAN button is pressed.)
Set the size of the characters displayed in the
case of alarms.
When the SET button is pressed, the SETUP
MENU screen returns.
ALARM ALARM
NORMAL DOUBLE
FUNCTION Screen