Preparations (Step 2 Setting the Network)
This function records the image to the memory of
¥When an alarm is activated, image recording can be carried out in one of the following two ways.
One way, local recording, saves images to the
1. Start up [V.Networks Setup Tool] and select [Recording]. |
|
To make new values effective, press [Apply] and then | . |
Trigger Recording |
|
For selecting the record starting trigger, the alarm input signal to start local recording.
For setting the recording time. Up to 60 seconds can be set both before and after an alarm input.
2. Frame Rate
Caution
●If the value for before a trigger is set to Ò0,Ó set a different value for after the trigger. Both values cannot be set to Ò0Ó at the same time.
●Because of the memory capacity of
mum recording time are not the same.
Example:
¥If 160x120 (30 fps)/320x240 (15 fps)/ 640x480 (5 fps) with a compression rate of 2, the actual recording time is 5 to 0 and 30 to 35 seconds, before and after a trigger respectively.
¥For the maximum recording (30 be- fore and 60 seconds after a trigger),
perform the setting as follows:
Image size | : 160x120 |
Frame rate | : 30 fps |
Compression rate | : 7 |
For setting the frame rate for local recording, select [Change the Recording FrameRate during trigger recording] and set the frame rate (30, 15, 10, 8, 7, 6, 5, 4, 3, 2 or 1). The default value is 30 fps.
32