Operations (Step 4 Setting with V.Networks Controller)
4-7 Alarm Setting (continued)
1Message
When an alarm is received, the message entered into the text box is displayed. The maximum number of characters that can be entered is 100.
2Recording
When an alarm is received, recording starts.
Stop button is pressed.
Stop 1min : Recording stops after 1 minute.
3Playing wave file
When an alarm is received, a specified Wave file is replayed. Press the [Browse] button to specify a Wave file.
Note
If a large Wave file (.wav) is selected, the alarm operation may become slow depend- ing on the PC performance.
Note | 4 Execute application file |
¥The [Stop 1min] mode is for conserving the hard disk space.
¥In this mode, recording stops after 1 minute even if recording has already started before the alarm input.
When an alarm is received, a specified program is executed. Press the [Browse] button to specify a program.
Note
Alarm Operation
The following settings are required for the operation of the alarm that has been set.
1.[Alarm Reg] is enabled in the [Setting] menu of the [V.Networks Controller.] (☞ Page 45)
2.Each alarm setting in [Alarm Setting] of [V.Networks Setup Tool] is enabled. (☞ Page 28)
Relay Alarm
When the relay alarm function is enabled, subsequent alarms will not be activated.