Camera unit/Inside the camera

TThis is when the dome cover, inner cover and outer case is removed. How to remove ( A Pg. 17 AMounting on a ceilingB Steps 3. to 5.)

W

Lens section

 

 

(A Pg. 13)

 

Behind the camera unit

J

 

V

 

 

P

K

U

 

 

T

Y

 

 

MAC address

 

S

 

L

R

X

M

Q

 

P

 

N

 

 

O

 

 

ENGLISH

H Power supply/Alarm signal cable (A Pg. 24, 26)

Signal name

Cable color

 

 

Alarm input 1

Pink

 

 

Alarm input 2

Blue

 

 

Alarm output 1

Orange

 

 

Alarm output 2

Yellow

 

 

GND

Brown

 

 

DC 12 V power supply+

Red

 

 

DC 12 V power supply-

Black

 

 

Note :

Do not use PoE together with DC 12 V power supply. Simultaneous connection will cause failure or malfunction.

I [10BASE-T/100BASE-TX(PoE)]Connector for LAN cable connection (RJ-45)(A Pg. 26)JStrapThis sheet connects the camera unit to the dome cover.
K Fastening screw (x3)

This is the screw head of the ceiling mounting bracket Q, which is used to embed the camera in the ceiling.

L [RESET] Reset button

This is a button for rebooting the camera. Press this button and release within 5 seconds to reboot the camera. It takes about 1 minute for the camera to reboot. During startup, [RESET] button is disabled.

Note :

Pressing the [RESET] button for 5 seconds or longer switches the camera to the service verification mode. Do not press the button for 5 seconds or longer.

M [MONITOR] Monitor terminal (RCA pin)(A Pg. 27)N Camera unitO Fall-prevention wire fastening hookP Fall-prevention wire (supplied) and wire mounting screw

Connect the camera unit N and the outer case C with the fall-prevention wire fastening screw O.

E-11