Selecting Mounting Method

The procedures differ according to the mounting method. Check the respective items before mounting.

Note :

To mount the camera using an electrical box, please check with your dealer or nearest JVC servicing center.

Mounting MethodMounting on a ceiling (A Pg. 17)Mounting directly on a ceiling or alongside a wall (A Pg. 20)Mounting by pulling cables horizontally (A Pg. 22)Mounting the camera to the electrical box(A Pg. 22)Warning

Special attention is required when mounting the camera to a wall or ceiling. Mounting operations should not be carried out by the users but by professional contracters. Failure to do so may cause the camera to fall and result in injuries and accidents.

JVC is not liable for any compensation if you drop the camera due to insecure mounting by not following the installation description. Pay careful attention during installation.

To prevent the camera from falling, ensure that it is connected to a firm place (ceiling slab or channel) using a fall-prevention wire.

Also pay careful attention to the length, strength, wiring and material (insulation quality) of the fall-prevention wire to be used.

The camera may drop if the mounting screws or nuts are not tightened securely. Check that the screws are tightened appropriately and securely.

Do not install the camera near lighting fixtures of high temperature, such as spot lights. It might result in failure or fires.

Mounting on a ceilingTThe thickness of the ceiling material should be between 9.5 mm and 22 mm.Setup1.Open a hole in the ceiling (R120 mm,4-3/4 inches)2.Draw the cables from the ceiling.

Draw the fall-prevention wire, LAN cable, power cable and alarm cable from the ceiling. These are mounted beforehand on the ceiling slab. (The fall-prevention wire is not supplied.)

Note :

Also pay careful attention to the length, strength, wiring and material (insulation quality) of the fall-prevention wire to be used.

For the fall-prevention wire, the inside diameter of the ring section to be mounted on the camera unit should be between R3.1 mm and R5.5 mm, and the outside diameter should be below R9 mm.

R120 mm

1

(4-3/4 inches)

 

Fall-prevention wire (not supplied)

Approx. 100 mm

Power cable, alarm(3-7/8 inches) cable

LAN cable

2

 

3.Remove the dome cover

As shown in the picture, hold the dome ring such that the position alignment mark is between your thumb and index finger. Turn the dome ring in the anti-clockwise direction and remove.

Dome ring Position

alignment mark

ENGLISH