Field angle adjustment

Loosen the fastening screw of the zoom adjustment ring, move the ring horizontally and adjust the image size.

Focus adjustment

Press the focus adjustment button. The Iris will open for approximately 30 seconds. Loosen the fastening screw of the focus adjustment ring, move the ring horizontally and adjust the focus.

Memo :

Repeat EField angle adjustmentF and EFocus adjustmentF 2 to 3 times and configure the settings.

After adjustment is complete, tighten and secure the respective fastening screws.

Pressing the focus adjustment button automatically activates the electronic shutter. The screen may flicker but this is not a malfunction.

Brightness adjustmentNormally, adjustment is not required. If necessary, adjust the Iris level.

To darken : Anti-clockwise direction (towards L)

To brighten : Clockwise direction (towards H)

Note :

For adjusting the brightness, do not conduct it within 30 seconds after pressing the focus button.

Memo :

When adjusting the iris level, set the AGC function to AOffB. Otherwise, when the level is turned too far toward L, the AGC function activates increasing sensitivity and the picture may look uneven.

For AAGC function settingsB, please refer to the [INSTRUCTIONS] (pdf) in the supplied CD-ROM.

Mounting the Dome CoverAfter all settings are complete, mount the dome cover.

Position alignment mark

1.

1.Mount the dome cover.

Align the camera with the position alignment mark on the dome cover and push in the dome cover to mount.

Note :

Push in the dome cover until you hear a click sound. Check that it has been securely mounted. Insecure mounting may cause the camera to fall or interfere with the LED (Status, Link, Act) display.

When the cover is removed again after mounting the dome cover, adjust the field angle.