Specify sunday, monday, tuesday, wednesday, thursday, friday or saturday for WeekOfDay. Specify on to enable the filter, off to disable the filter.

The changes to filter of alarm action is saved by /api/param?application.event(Number).status=restart. Allowed users admin, operator

Getting Alarm Filter Time from VN-V686

Format /api/param?application.event(Number).filter(WeekOfDay).time

Example When Getting Time of Sunday filter of Alarm No. 1

/api/param?application.event(1).filter(sunday).time

Example of Response application.event(1).filter(sunday).time=000000-240000&200 OK

Interpretation Acquire filter time of the alarm action for the specified alarm number. Up to 5 alarm actions can be specified, and periodic FTP is assigned to event No.6, therefore the number of alarm(number) can be set between the range of 1 to 6. Note that alarm numbers are different from the alarm input pin numbers.

Specify sunday, monday, tuesday, wednesday, thursday, friday or saturday for WeekOfDay. Start time and end time is returned in the format like hhmmss-hhmmss. Start time can be from 000000 to 235959. End time can be from 000001 to 240000.

Allowed users admin, operator

Setting Alarm Filter Time for VN-V686

Format /api/param?application.event(Number).filter(WeekOfDay).time=data

Example When setting Sunday filter time of Alarm No. 1

/api/param?application.event(1).filter(sunday).time=010200-040500

Example of Response

application.event(1).filter(sunday).time&202

Accepted(application.event(1).status=restart)

Interpretation Set filter time of the alarm action for the specified alarm number. Up to 5 alarm actions can be specified, and periodic FTP is assigned to event No.6, therefore the number of alarm(number) can be set between the range of 1 to 6. Note that alarm numbers are different from the alarm input pin numbers.

Specify sunday, monday, tuesday, wednesday, thursday, friday or saturday for WeekOfDay.

Specify start time and end time in the format like hhmmss-hhmmss. Start time can be from 000000 to 235959. End time can be from 000001 to 240000. Start time must be earlier than end time.

The changes to filter of alarm action is saved by /api/param?application.event(Number).status=restart. Allowed users admin, operator

Getting Alarm Filter Type from VN-V686

Format /api/param?application.event(Number).filter(WeekOfDay).type

40

Page 40
Image 40
JVC VN-V686U manual Getting Alarm Filter Time from VN-V686, Setting Alarm Filter Time for VN-V686