Getting Access Interval Unit of NTP from VN-V686
Format /api/param?network.ntp.unit
Example of Response network.ntp.unit=hour&200 OK
Interpretation Acquire the unit of interval for accessing the NTP server. "min", "hour" or "day" is returned.
Allowed users admin, operator, user
Setting Access Interval Unit of SNTP for VN-V686
Format /api/param?network.ntp.unit=data
Example /api/param?network.ntp.unit=day
Example of Response
network.ntp.unit&202 Accepted(network.ntp.status=restart)
Interpretation Change the unit of interval for accessing the NTP server. Specify "min", "hour" or "day". To
validate the change, use "network.ntp.status=restart" API.
Allowed users admin, operator
Getting Time from VN-V686
Format /api/param?system.date
Example of Response system.date=20050614171537&200 OK
Interpretation Acquire the time from the built-in clock of VN-V686. Time is arranged in the order of year, month,
day, hour, minute and second. Year is denoted in a 4-digit decimal number, and month, day, hour, minute and second
are denoted in 2-digit decimal numbers.
Allowed users admin, operator, user
Setting Time for VN-V686
Format /api/param?system.date=data
Example /api/param?system.date=20050614171537
Example of Response system.date&200 OK
Interpretation Change the time of the built-in clock in VN-V686. Specify in the order of year, month, day, hour,
minute and second. Specify year in a 4-digit decimal number, and month, day, hour, minute and second in 2-digit
decimal numbers.
Allowed user admin
Getting Timezone from VN-V686
Format /api/param?system.timezone
Example of Response system.timezone=Pacific&200 OK
Interpretation Acquire the timezone from VN-V686. Character strings in the following table will be returned.
86