Example When Getting Type of Sunday filter of Alarm No. 1

/api/param?application.event(1).filter(sunday).type

Example of Response application.event(1).filter(sunday).type=mask&200 OK

Interpretation Acquire filter type of the alarm action for the specified alarm number. Up to 5 alarm actions can be specified, and periodic FTP is assigned to event No.6, therefore the number of alarm(number) can be set between the range of 1 to 6. Note that alarm numbers are different from the alarm input pin numbers.

Specify sunday, monday, tuesday, wednesday, thursday, friday or saturday for WeekOfDay. "mask" or "unmask" is returned. When the setting is mask, alarm action is disabled during the filter time. When the setting is unmask, alarm action is enabled during the filter time.

Allowed users admin, operator

Setting Alarm Filter Type for VN-V686

Format /api/param?application.event(Number).filter(WeekOfDay).type=data

Example When setting Sunday filter type of Alarm No. 1 to be unmask

/api/param?application.event(1).filter(sunday).type=unmask

Example of Response

application.event(1).filter(sunday).type&202

Accepted(application.event(1).status=restart)

Interpretation Set filter type of the alarm action for the specified alarm number. Up to 5 alarm actions can be specified, and periodic FTP is assigned to event No.6, therefore the number of alarm(number) can be set between the range of 1 to 6. Note that alarm numbers are different from the alarm input pin numbers.

Specify sunday, monday, tuesday, wednesday, thursday, friday or saturday for WeekOfDay.

Specify mask or unmask. When the setting is mask, alarm action is disabled during the filter time. When the setting is unmask, alarm action is enabled during the filter time.

The changes to filter of alarm action is saved by /api/param?application.event(Number).status=restart. Allowed users admin, operator

Getting Alarm Trigger from VN-V686

Format /api/param?application.event(Number).trigger

Example When Getting Trigger of Alarm No. 1

/api/param?application.event(1).trigger

Example of Response application.event(1).trigger=m1&200 OK

Interpretation Acquire Trigger of the alarm action for the specified alarm number. Up to 5 alarm actions can be specified, and periodic FTP is assigned to event No.6, therefore the number of alarm(number) can be set between the range of 1 to 6. Note that alarm numbers are different from the alarm input pin numbers.