INSTALLATION AND CONNECTION

LAYING CABLES AND CONNECTING THE TURNTABLE

Lay the master coaxial cable (marked red) to the UFS 940sw and the second coaxial cable to the second receiver. If you are not using a second receiver, we recommend that you lay the second coaxial cable in any case, so that it is available should you ever need it.

Lay the turntable power supply cable (3-pin plug) to the battery.

Avoid laying the cables across sharp edges and secure the cables against possible chafing points.

Connect the master coaxial cable (coming from the turntable) to the “IF IN” F socket on the rear of the UFS 940sw.

Place the infra-red sensor for the receiver close to or directly on top of the TV set and lay the cable to the UFS 940sw. Connect the 6-pin Western connector at the rear to the socket marked “IR REMOTE IN” (see also “Installation of the UFS 940sw receiver” in this section).

Note: Lay the Cinch cable supplied with the CAP 910. Take great care to plug the cable into the correct socket!

CONNECTING TO THE UFS 940SW

The receiver must be connected to no other power supply than 12 V DC. The receiver’s earth connection must be connected to the negative pole of the motor home or caravan battery.

Isolate the on-board power supply (master switch “off” or disconnect the positive pole of the on-board power supply battery) before commencing the following work:

Connect the power cable supplied (depending on the power supply available in your motor home

or caravan, either a 12 V supply or a 230 V supply via a power supply unit) to the “

plug connector on the receiver.

 

Make sure that the “inline” integrated fuse (5 A) of the cable is fully plugged in and is intact. If the fuse blows, the source of the fault must first be eliminated. The fuse must only ever be replaced by a fuse with the same rating (5 A).

The fuses in the cable and in the receiver must never be by-passed – cable fire hazard!

At the connecting point for the power cable, the voltage must not fall below 10.9 V even with a load of 12 A. Otherwise optimum functioning can no longer be guaranteed.

Connect the power cable to the respective socket in your motor home or caravan (12 V or 230 V).

23

Page 23
Image 23
Kathrein cap910 manual Laying Cables and Connecting the Turntable, Connecting to the UFS 940SW