Frequency Display and Entering Frequency

Sat measurement

Frequency Display and Entering Frequency

To measure the level of a received signal, you must first enter the desired frequency. The LC display shows the frequency and the measured level. You can enter frequency values from 920 MHz to 2150 MHz in steps of 100 kHz.

Overview of commands in Entering Frequency (SAT)

ë

 

 

FR:1288.0MHz

SAT

LEV: 66.5dBuV

￿

 

 

 

 

Example

[SAT/TV] Switch over to SAT reception

[0]...[9] Enter frequency

[+][-]You can alter frequency in steps of 100 kHz

[ENTER] Confirm entry

LC display:

Frequency: 1288 MHz

Mode: SAT

Level: 66.5 dBìV

Enter frequency 1508 MHz

Press [1] [5] [0] [8] [E NTER]

LC display:

 

 

FR:1508.0MHz

SAT

LEV: 86.5dBuV

￿

 

 

 

 

Frequency: 1508 MHz

Mode: SAT

Level: 86.5 dBìV

Note

+

A + or – in the display means that MSK 24 has not been tuned in exactly to the desired carrier. Use the [+] and [-]buttons to adjust the frequency for the best possible reception. When a vertical line appears in the display, the frequency has the best possible setting.

Press [ENTER] to complete the frequency entry.

The last frequency setting is retained even when the MSK 24 is switched off provided it was made using "numerical entries" and concluded with "MHz".