Overview of commands in Command Byte

Sat measurement

Overview of commands in Command Byte

 

The MSK 24 can send commands in accordance with DiSEqC 1.0 but it

ë

cannot receive them. All commands that require DiSEqC 2.0 (to send and

receive) are shown in grey in the table.

 

 

 

 

 

Commands shown in

bold type are used

preferentially

for Kathrein

 

switching matrices.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Hex

Command

Description

 

 

 

 

Number of

 

byte

 

 

 

 

 

 

 

data bytes

 

00

Reset

Reset DiSEqC microcontroller

 

-

 

01

Clr Reset

Clear reset flag

 

 

 

 

-

 

02

Standby

Switch off the peripheral power

 

-

 

 

 

supply unit

 

 

 

 

 

 

03

Power on

Switch on the peripheral power

 

-

 

 

 

supply unit

 

 

 

 

 

 

04

Set Content

Set the contention flag

 

 

-

 

05

Contend

Feedback only if the contention

 

-

 

 

 

flag has been set

 

 

 

 

 

 

06

Clr Content

Clear contention flag

 

 

 

-

 

07

Address

Feedback only if the contention

 

-

 

 

 

flag has not been set

 

 

 

 

 

08

Move C

Change

address

if

contention

 

1

 

 

 

flag has been set

 

 

 

 

 

 

09

Move

Change

address

if

contention

 

1

 

 

 

flag has not been set

 

 

 

 

 

10

Status

Read status register flags

 

 

-

 

11

Config

Read configuration flags

 

 

-

 

14

Switch 0

Read switching

status

flags

 

-

 

 

 

(Committed Port)

 

 

 

 

 

 

15

Switch 1

Read

switching

state

flags

 

-

 

 

 

(uncommitted port)

 

 

 

 

 

 

16

Switch 2

Expansion option

 

 

 

 

-

 

17

Switch 3

Expansion option

 

 

 

 

-

 

20

Set LO

Call up the low local oscillator

 

-

 

 

 

frequency

 

 

 

 

 

 

21

Set VR

Call up vertical polarization or

 

-

 

 

 

circular

polarization

with

right

 

 

 

 

 

rotation

 

 

 

 

 

 

 

22

Set Pos A

Select satellite position A

 

 

-

 

23

Set S0A

Select switch option A

 

 

-

 

24

Set Hi

Call up the high local

 

-

 

 

 

oscillator frequency

 

 

 

 

 

25

Set HL

Call up vertical polarization or

 

-

 

 

 

circular

polarization

with

left

 

 

 

 

 

rotation

 

 

 

 

 

 

 

26

Set Pos B

Select satellite position B

 

 

-

 

27

Set S0B

Select switch option B

 

 

-

 

28

Set S1A

Call up matrix S1 input A (input

 

-

 

 

 

B inactive)

 

 

 

 

 

 

29

Set S2A

Call up matrix S2 input A (input

 

-

29

Page 29