Kathrein MSK 24 manual Overview of commands in Framing Byte, Press buttons 2ndF SAT-CTRL

Models: MSK 24

1 56
Download 56 pages 38.36 Kb
Page 27
Image 27
Press buttons [2ndF] [SAT-CTRL]

Sat measurement

Example

0

SAT-CTRL LNB=1

V-SEC=2 DiSEqC=3

SAT-CTRL menu

DiSEqC-Framing

￿

DiSEqC menu

DiSEqC-COMMAND E0 00 24 >

DiSEqC menu

Note

+

You want to test the Kathrein matrix EXR 22. The command set for the matrix EXR 22 is E0 00 24 (LNB High) and E0 00 20 (LNB Low).

Call up DiSEqC:

Press buttons [2ndF] [SAT-CTRL]

Press button [3] to call up the DiSEqC control.

You can now enter the data bits for each code word using the buttons [0] to [9] and [./S]. Send the control command by pressing [ENTER]. The > symbol indicates that the control command has been sent.

The command set to control the Kathrein matrix EXR 22 has been entered and sent.

You can find the DiSEqC command sets for the Kathrein matrices EXR 20, EXR 22 and the 9xx series in the Technical Appendix.

Overview of commands in Framing Byte

ë

HEX

Description

Byte

 

E0

Command from master, single transmission

E1

Command from master, repetitive transmission

E2

Command from master, answer expected, first transmission

E3

Command from master, answer expected, repeated

 

transmission

E4

Answer from slave, "OK", no error detected

E5

Answer from slave, command not supported by slave

E6

Answer from slave, parity error detected

E7

Answer from slave, command not detected

27

Page 27
Image 27
Kathrein MSK 24 manual Overview of commands in Framing Byte, Press buttons 2ndF SAT-CTRL, Sat measurement