TROUBLESHOOTING GUIDE
Models DP920PFG & DU920PFG
PRECAUTIONS TO BE OBSERVED WHILE TROUBLESHOOTING
AND DIAGNOSING PROBLEMS
Always check wiring harness and connectors before initiating any test procedures.
Disconnect electric power from the dishwasher before touching the printed circuit boards or
Voltage checks should be made by inserting meter probes beside the wires in the connector blocks with the electric power source on and the connector block plugged in.
Resistance checks should be made on components with the electric power off and the connector blocks disconnected.
TROUBLESHOOTING GUIDE
PROBLEM |
| POSSIBLE CAUSES |
| CORRECTION/TEST |
|
|
|
|
|
Dishwasher does not run or | 1. | Door is not latching properly. | 1. | Check to make sure handle link |
stops during a cycle |
|
|
| is properly seated in door latch |
|
|
|
| assembly. Check that the door |
|
|
|
| switch is opening and closing |
|
|
|
| properly. |
| 2. | Child lock is "ON". | 2. | Turn child lock "OFF" |
| 3. | Wash Cycle not set properly. | 3. | Review setting Wash Cycles in |
|
|
|
| the Use and Care Guide. |
| 4. | Household fuse blown or circuit | 4. | Have a qualified electrician check |
|
| breaker tripped. |
| the circuit breaker or fuse. |
| 5. | Washer is not wired into a circuit with | 5. | Have customer call a qualified |
|
| proper voltage. |
| electrician. |
|
|
|
|
|
Dishwasher will not fill | 1. | Overflow protection float is stuck in | 1. | Check that the overflow |
|
| "up" position. |
| protection float is free to move |
|
|
|
| "up" and "down". Check that the |
|
|
|
| overfill switch in opening and |
|
|
|
| closing properly. |
| 2. | Fill valve is inoperable. | 2. | Check for continuity between |
|
|
|
| contacts on fill valve. |
| 3. | Control board is inoperable. | 3. | Check for 110VAC between |
|
|
|
| and |
|
|
|
|
|
Dishwasher will not drain | 1. | Air gap (if installed) is clogged. | 1. | Follow air gap manufacturer's |
| 2. | Pump motor is inoperable |
| direction for cleaning. |
| 2. | Disconnect pump motor from | ||
|
|
|
| wiring harness and check for |
|
|
|
| continuity between V & BU, V & |
| 3. | Control board is inoperable. |
| GY and V & Y. |
| 3. | Check for 110VAC between P10 | ||
|
|
|
| and P3, P10 and P5 and P10 |
|
|
|
| and P4. |
|
|
|
|
|
Dishwasher will not | 1. | Heater element burned out. | 1. | Check for continuity between the |
dry dishes |
|
|
| terminals of the heater element. |
|
|
|
| Check for 110VAC between P6 |
| 2. |
| and P8. | |
| 2. | Check for continuity between | ||
|
|
|
| terminals of the |
|
|
|
| thermostat. |
|
|
|
|
|
37