Kenmore DU800DWG, DU910PFG, DU890DWG, DU920PFG, GU960SCG, DU850DWG manual Servicing the Pump Assembly

Models: DU810DWG DU800DWG DU801DWG DU840DWG DU805DWG DP840DWG DU850DWG GU960SCG DU920PFG DU890DWG DU910PFG

1 66
Download 66 pages 32.08 Kb
Page 9
Image 9
Servicing the Pump Assembly

4.Disconnect the drain hose from the drain valve by loosening the Hex-head screw on the hose clamp. (Fig. 1-7)

5.Disconnect the pump inlet hose from the pump and motor assembly. (Fig. 1-7)

6.Remove the pump and motor assembly from the bottom of the dishwasher.

PUMP INLET

HOSE

DRAIN

HOSE

Fig. 1-7

NOTE: Once the pump and mo- tor assembly has been removed from the tub, the pump outlet grom- met can be removed from the inside of the tub. Check the pump outlet grommet for wear or damage and replace it if necessary.

The motor can be removed from the pump assembly by removing the three T-20 Torx screws securing the motor to the pump assembly. (Fig. 1-8)

TORX

SCREWS

NOTE: When reinstalling the motor make sure the keyed motor shaft lines up with the pump impel- ler.

Fig. 1-8

Servicing the Pump Assembly

 

 

The pump impeller can be accessed by using

 

 

an adjustable slip-nut wrench to turn the

 

 

disk mount assembly counterclockwise.

 

 

Once the disk mount assembly is removed,

 

 

the impeller can be removed. (Fig. 1-9)

 

SLIP-NUT WRENCH

 

 

 

 

TORX

 

Fig. 1-9

SCREWS

 

 

The drain valve can be accessed by removing

 

 

the four (4) T-20 Torx screws securing the drain

 

 

outlet cover to the pump assembly. The drain

 

 

cover seal, diaphragm and diaphragm ring can

 

 

be removed and replaced. (Fig. 1-10)

 

Fig. 1-10

 

 

5

Page 9
Image 9
Kenmore DU800DWG, DU910PFG, DU890DWG, DU920PFG, GU960SCG, DU850DWG, DP840DWG, DU805DWG, DU840DWG manual Servicing the Pump Assembly