Laundry tub drain system (view C)
The laundry tub needs a minimum 20 gal. (76 L)capacity. The top
of the laundry tub must beat least 39" (99 cm) above the floor
and no higher than 96" (244 cm) from the bottom of the washer.
Floor drain system (view D)
The floor drain system requires a siphon break that may be
purchased separately. See "Tools and Parts."
The siphon break must be a minimum of 28" (71 cm) from the
bottom of the washer. Additional hoses might be needed.
C D
If codes permit and a separate ground wire is used, it is
recommended that aqualified electrician determine that the
ground path is adequate.
Do not ground to a gas pipe.
Check with a qualified electrician if you are not sure the
washer is properly grounded.
Do not have afuse in the neutral orground circuit.
Electrical Shock Hazard
Plug into a grounded 3prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
A 120 volt, 60 Hz., AC only, 15- or20-amp, fused electrical
supply is required. A time-delay fuse or circuit breaker is
recommended. Itis recommended that a separate circuit
serving only this appliance be provided.
This washer is equipped with a power supply cord having a
grounded 3 prong plug.
To minimize possible shock hazard, the cord must be
plugged into amating, grounded 3 prong outlet, grounded in
accordance with local codes and ordinances. Ifa mating
outlet is not available, it is the personal responsibility and
obligation of the customer to have the properly grounded
outlet installed by a qualified electrician.
GROUNDING iNSTRUCTiONS
For agrounded, cord=connected washer:
This washer must be grounded, in the event of a malfunction
or breakdown, grounding will reduce the risk of electrical
shock by providing apath of least resistance for electric
current. This washer is equipped with a cord having an
equipment-grounding conductor and a grounding plug. The
plug must be plugged into an appropriate outlet that is
properly installed and grounded in accordance with all local
codes and ordinances.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric shock.
Check with a qualified electrician or serviceman if you are in
doubt as to whether the appliance is properly grounded.
Do not modify the plug provided with the appliance - if itwill
not fitthe outlet, have a proper outlet installed by a qualified
electrician.
For apermanently connected washer:
This washer must be connected to a grounded metal,
permanent wiring system, or an equipment grounding
conductor must be runwith the circuitconductors and
connected to the equipment-grounding terminal or lead on
the appliance.
6