4= Using pliers, tighten the coupling with an additional

3= Fasten the

drain hose to the laundry tub leg or drain

two-thirds turn.

standpipe

with the beaded tie strap. See view A or B.

NOTE: Do not overtighten or use tape or sealants on the

 

 

valve. Damage to the valves can result.

 

 

5= Attach the cold water hose to the inlet valve labeled cold.

6.Screw on coupling by hand until it is seated on the washer.

7.Using pliers, tighten the coupling with an additional two- thirds turn.

NOTE: Do not overtighten or use tape or sealants on the valve. Damage to the valves can result.

Check for leaks

Turn on the water faucets and check for leaks. A small amount of water might enter the washer. You will drain this in a later step.

NOTE: Replace inlet hoses after 5 years of use to reduce the risk of hose failure. Record hose installation or replacement dates for future reference.

If you connect only one water hose, you must cap off the remaining water inlet port.

Periodically inspect and replace hoses if bulges, kinks, cuts, wear, or leaks are found.

1= Drape the power cord over the console.

2.Remove any cardboard used to move washer.

Beaded tie strap

BC

If the washer faucets and the drain standpipe are recessed, put the formed end of the drain hose into the standpipe. Tightly wrap the tie strap around the water inlet hoses and the drain hose. See view C.

Lew; e e

Excessive Weight Hazard

Use two or more people to move and install washer. Failure to do so can result in back or other injury.

One washer foot has been installed at a different height on your new washer. The other three feet were preset at the factory. Properly leveling your washer will minimize noise and vibration.

1.Slide the washer to its final location.

2.Push on upper front panel to be sure the washer is on its rear feet.

3.Lower right front foot until it contacts the floor. By hand, firmly rotate foot as much as an additional 1V2turns. The other three

feet have been preset at the factory.

9