Battery Saver

This transceiver has been designed to give you the most out of your battery power. The battery saver function decreases the amount of power used when a signal is not being received and no operations are being performed.

While using the transceiver, battery saver will automatically switch ON after 5 seconds have elapsed with no operations or received calls. Operating the transceiver or receiving a call will switch this feature OFF until 5 seconds of non-operation occurs again.

To turn this function on or off:

1With the transceiver power OFF, press and hold the MENU key while turning the transceiver power ON (for 1 second).

2Press the or key to select “  ”.

3Press the MENU key then press or to select “  ”

(battery saver on) or “  ” (battery saver off).

4Press the MENU key to exit the selection.

5Press the PTT, MON, or CAL key to exit Setting Mode.

Note: While the Battery Saver is operating, the LED may flash green when receiving a QT/DQT signal which does not match the QT/DQT tone/code set up in your transceiver.