Gas Connection Requirements

For Models Equipped for Natural Gas

Natural Gas

 

LP Gas Conversion Using a Local LP Gas Supply

Built-in grill models are equipped for use with Natural gas. They are design-certified by CSA International for LP (propane or butane) gases with appropriate conversion.

Built-in models are set for Natural gas use and have a pressure regulator with ½" female pipe threads.

A

 

 

B

D

C

 

A. Grill gas pipe

B. New CSA International approved “outdoor” flexible gas supply line

C. Rear of grill

D. To Natural gas supply

The supply line shall be equipped with an approved shutoff valve. This valve should be located in the same area as the grill and should be in a location that allows ease of opening and closing. Do not block access to the shutoff valve. The valve is for turning on or shutting off gas to the grill.

B

A

C

A. Gas supply line

B. Shutoff valve “open” position

C. To grill

Conversion must be made by a qualified person. A qualified Natural gas technician shall provide the LP gas supply to the selected grill location in accordance with the National Fuel Gas Code ANSI Z223.1/NFPA 54 - latest edition, and local codes.

To convert to LP gas, the LP Gas Conversion Kit Part Number W10118099 must be used. Follow instructions included with kit.

A

 

 

B

D

C

 

A. Grill gas pipe

B. New CSA International approved “outdoor” flexible gas supply line

C. Rear of grill

D. To local gas supply

LP Gas Conversion Using a 20 lb LP Gas Fuel Tank

To convert to LP gas, the LP Gas Conversion Kit Part Number W10118099 must be used. Follow instructions included with kit. A 20 lb LP gas fuel tank must be purchased separately.

13

Page 13
Image 13
KitchenAid KBNU487VSS, W10175730A, KBNU271VSS, KBNU367TSS Natural Gas LP Gas Conversion Using a Local LP Gas Supply