Gas Connection to Natural Gas or Local LP Gas
WARNING
Explosion Hazard
Use a new CSA International approved “outdoor” gas supply line.
Securely tighten all gas connections.
If connected to LP, have a qualified person make sure gas pressure does not exceed 11” (28 cm) water column.
Examples of a qualified person include:
licensed heating personnel,
authorized gas company personnel, and authorized service personnel.
Failure to do so can result in death, explosion, or fire.
This installation must conform with local codes and ordinances. In the absence of local codes, installations must conform with either the National Fuel Gas Code ANSI Z223.1 - latest edition, or
Copies of the standards listed above may be obtained from:
CSA International
8501 East Pleasant Valley Rd.
Cleveland, Ohio
National Fire Protection Association One Batterymarch Park
Quincy, Massachusetts 02269
1.Make gas connections.
A combination of pipe fittings must be used to connect the grill to the existing gas line.
■If local codes permit, use an outdoor flexible stainless steel tubing gas connector,
■
A
B
C
A. New CSA International approved “outdoor” flexible gas supply line
B. Rear of grill
C. To Natural gas or Local LP gas supply
†®TEFLON is a registered trademark of E.I. Du Pont De Nemours and Company.
2.Open the manual shutoff valve in the gas supply line. The valve is open when the handle is parallel to the gas pipe.
A
B
A. Closed valve
B. Open valve
3.Test all connections by brushing on an approved noncorrosive
4.The batteries are not factory installed. The
Plug in Grill
NOTE: This
1.Plug the
A
A.Single-prong plug
2.Locate or build a
3.Mount the power transformer to the mounting surface using 4 #8 screws (not supplied) that are the proper type and length for the transformer and the mounting surface. It must be mounted with the wire for the
NOTE: The cord must be properly mounted with a cord retention device so that its