Conversion from LP Gas to Natural Gas
Installation of the regulator
1.Turn off the main gas supply valve.
2.Unplug grill or disconnect power.
3.Disconnect 20 lb LP gas fuel tank (if present).
4.Turn off all burner control valves.
5.Remove rear cover and 2 screws.
6.Use adjustable wrench to remove LP hose regulator from brass elbow. Use adjustable wrench to remove brass elbow from shutoff valve.
A
B
C
D
A.Manifold
B.Brass elbow
C.Rear of grill
D.Gas pressure regulator/hose assembly
7.Apply pipe sealant to the threads of the brass connector. Use pipe thread sealant that is certified for use with LP gas.
8.Use adjustable wrench to install brass connector (supplied) to shutoff valve.
NOTE: The arrow on the regulator must be pointing toward the brass connector.
9.Use pipe wrench to install the convertible regulator. Brass cap will be facing up when tight.
AB
A. Brass elbow
B. Convertible regulator
10.To make sure the regulator is set for Natural gas, use adjustable wrench to remove brass cap on appliance regulator.
11.Examine the stem on the brass cap. If the letters “NAT” are not showing on the end of the plastic stem farthest away from the brass cap, remove stem from cap, turn it over and snap stem back into the cap so the letters “NAT” are at the end of the stem farthest away from the brass cap.
NAT
12.Reinstall cap onto convertible regulator.
Change the main grill burner valve orifices
1.Manually remove all of the grates, sear plate, and burners.
2.Remove the 2 screws that hold the burner in place. Remove gas burner from the grill.
A
A. Two screws
20