Kodak i1800 Series manual Input elevator too full, feed module

Models: i1800 Series

1 101
Download 101 pages 19.43 Kb
Page 92
Image 92
Input elevator too full, feed module

Messages

ID#

Operator Message

Input elevator too full, feed module

297

• There is too much paper in the input elevator and it is holding

missing or broken

 

the feed module up. The maximum input elevator capacity is

 

 

500 sheets. Remove some documents from the input elevator.

 

 

• The feed module is not installed properly. See Chapter 5,

 

 

Maintenance, for correct installation procedures.

 

 

• If the problem persists, call Service.

 

 

 

Invalid job setup

4

The image processing values sent by the host are invalid or in

 

 

conflict with one another.

 

 

• Check the job settings for illegal combinations. Refer to the

 

 

Image Processing Guide for valid values.

 

 

 

Jam in transport

30

A document is lodged in the transport.

 

 

• Remove the documents that have been scanned from the

 

 

output tray.

 

 

• Open the pod.

 

 

• Remove any jammed documents from inside the transport.

 

 

• Close the pod.

 

 

NOTE: The following procedure is a general guideline. Your

 

 

procedure may be different depending on how your

 

 

application is set up.

 

 

• Verify the last document that was scanned correctly.

 

 

• Place any documents that were not scanned at the top of the

 

 

batch.

 

 

• Place the documents in the input elevator and begin scanning.

 

 

One or more documents that passed through the transport were

 

 

not scanned.

 

 

• Refeed all documents for which images were not obtained.

 

 

 

Lamps not ready for calibration

107

Calibration was attempted before the lamps were warmed up.

 

 

• Wait until the lamps have completely warmed (90 seconds)

 

 

and try the calibration again.

 

 

 

Lamps not ready for scanning

359, 19

Scanning was attempted before the lamps were warmed up.

 

 

• Wait for the message Lamps ready for scanning to be

 

 

displayed and scan again.

 

 

 

Lamps ready for calibration

108

Informational message. The lamps are warmed and a calibration

 

 

can be performed now, if needed. This does not indicate that a

 

 

calibrate is needed.

 

 

 

Lamps ready for scanning

280

Informational message. The lamps are warmed and scanning

 

 

can be initiated.

Lamps timed out

355

Informational message. The lamps were turned off due to

 

 

inactivity.

 

 

 

No paper input elevator

46

The scanner was started with an empty input elevator or the

 

 

portion of the document that is covering the paper present

 

 

sensor is too dark (the back side of the bottom page).

 

 

• Place the documents you want to scan in the input elevator

 

 

and try again.

 

 

• Offset the document until the paper present sensor detects it.

 

 

 

A-61555 March 2007

6-7

Page 92
Image 92
Kodak i1800 Series manual Input elevator too full, feed module