Diagnostics
Voltage Specifications - General Parts
Part | Procedure | Voltage |
|
|
|
|
|
FOCUS MOTOR | None | 8.5 V AC |
|
|
|
|
|
CYCLE SOLENOID | Press the REVERSE BUTTON. | 39 W, 18.7 V DC |
|
|
|
|
|
RACK SOLENOID | None | 39 W, 10 V AC |
|
|
|
|
|
LAMP RECEPTACLE | None | 82 V AC, approximately |
|
|
| LAMP MODULE installed |
|
|
|
|
|
DROPPING RESISTOR | Move to the LO LAMP position. | 3.0 W, 10.6 V AC drop across |
|
|
|
|
|
|
|
|
|
Power, Illumination, and Cooling Malfunctions |
|
|
Malfunction |
| Check |
|
|
|
The MOTOR does not operate. | 1. | Check the continuity across the THERMAL |
|
| FUSE ASSEMBLY, and MOTOR FUSE. |
| 2. | Check that the primary voltage on the MAIN |
|
| MOTOR is correct. |
| 3. | Check that the voltage on POWER |
|
| SWITCH is correct. |
|
| |
The FAN does not operate, MOTOR operates. | 1. Check that the FAN BELT is not broken. | |
| 2. | Check and remove obstructions in the FAN |
|
| area. |
|
|
|
There is excessive noise in the FAN. | 1. | Check and remove obstructions in the FAN |
|
| area. |
| 2. | Check that the tension is correct on the |
|
| FAN BELT. |
| 3. | Check that the FAN BELT is clean. |
| 4. | Check the condition of the BEARING in the |
|
| FAN ASSEMBLY. |
|
|
|
The LAMP does not operate. | 1. | Check the LAMP for damage. |
| 2. | Check the LAMP RECEPTACLE |
|
| ASSEMBLY for damage and correct |
|
| voltage. |
| 3. | Check the LAMP TERMINAL ASSEMBLY |
|
| in the LAMP MODULE ASSEMBLY for |
|
| damage. |
|
|
|
The LO LAMP does not operate. | 1. | Check that the W of the DROPPING |
|
| RESISTOR is 3 W. |
| 2. | Check that the wire connections on the |
|
| POWER SWITCH are correct. |
| 3. | Check the POWER SWITCH for correct |
|
| operation. |
|
|
|
There is an obstruction in the light path. | 1. | Check the DARK SHUTTER for correct |
|
| operation. See the adjustment for the |
|
| DARK SHUTTER. |
| 2. | Check the LIGHT BAFFLE in the |
|
| MECHANISM for damage; it should not |
|
| cause a jam in the SHUTTER. |
|
|
|
47 |