SERVICE MANUAL

Malfunction

 

Check

 

 

TIMER does not operate

1. Check the VARIABLE RESISTOR for

 

 

correct operation and install a new part if

 

 

necessary.

 

2.

Move the TIMER BUTTON forward and

 

 

backward; use a DVM to check for changes

 

 

in W.

 

3.

Energize the projector and move the TIMER

 

 

to “S”.

 

 

• Check the voltages on CR3, Q3, and

 

 

Q4, see the voltage table.

 

 

 

DARK SHUTTER SWITCH does not operate

1.

Energize the projector and release the

 

 

DARK SHUTTER to allow projection.

 

2.

Check for continuity between PINS 4 and 5

 

 

on the SPECIAL APPLICATIONS PLUG.

 

3.

Press the “FORWARD” or “REVERSE”

 

 

BUTTONS to close the DARK SHUTTER.

 

4.

In the closed position, the DVM should

 

 

measure 0 W.

 

5.

If this procedure does not correct the

 

 

malfunction, install a new DARK SHUTTER

 

 

SWITCH.

 

 

 

ZERO POSITION SWITCH does not operate

1.

Deenergize the projector.

 

2.

Check for continuity between PINS 1 and 3

 

 

on the SPECIAL APPLICATIONS PLUG.

 

3.

Install a SLIDE TRAY.

 

4.

Rotate the SLIDE TRAY to engage the

 

 

ZERO POSITION SWITCH, the DVM

 

 

should measure 0 W.

 

5.

If the W measurement is not correct, see

 

 

the adjustment for the ZERO POSITION

 

 

SWITCH. Install a new ZERO POSITION

 

 

SWITCH if necessary.

 

 

After the FOCUS MOTOR energizes and

1. Remove R3 and install a new 68K W 1/4 W

moves, the FOCUS MOTOR oscillates.

 

RESISTOR (part 220040).

 

2.

If there is still a malfunction, install a new

 

 

PHOTOCELL.

 

 

 

50

30APR96 – SM4530-1

Page 50
Image 50