Diagnostics

Malfunction

 

Check

 

 

 

AUTO FOCUS MOTOR operates continually

1.

Install the TARGET SLIDE TL-3002 in the

 

 

GATE MECHANISM.

 

2.

Check that the alignment of the TARGET

 

 

and NULL is correct. If not, see the

 

 

Adjustments section.

 

3.

Check for a light leak:

 

 

• Install a different LAMP MODULE

 

 

ASSEMBLY. If the FOCUS MOTOR

 

 

stops operating continually, install a

 

 

new LAMP MODULE ASSEMBLY.

 

4.

Check that the voltages across the

 

 

PHOTOCELL are correct. The voltage from

 

 

1 to 2 is 14.5 V ac. The voltage from 2 to 3

 

 

is 14.5 V ac. The voltage from 1 to 3 is 29

 

 

V ac.

 

5.

Check that the PHOTOCELL HOUSING

 

 

has 2 FILTERS.

 

6.

Install a new PHOTOCELL.

 

7.

Check the components on the CIRCUIT

 

 

BOARD for damage.

 

 

 

AUTO FOCUS MOTOR operates continually in

1.

Check that the wires of the AUTO FOCUS

forward only or reverse only and does not

 

MOTOR are in the correct position; the blue

operate (stops) in the null position.

 

wire goes to the mark on the AUTO FOCUS

 

 

MOTOR.

 

 

AUTO FOCUS adjusts after REMOTE use

1. Do the adjustment for the CLAMP LEVER

 

 

ASSEMBLY.

 

 

 

SM4530-1 – 30APR96

53

Page 53
Image 53
Kodak E-PLUS SLIDE, KKE PLUS, J-E PLUS service manual Check that the alignment of the Target