Diagnostics
Malfunction |
| Check |
|
|
|
AUTO FOCUS MOTOR operates continually | 1. | Install the TARGET SLIDE |
|
| GATE MECHANISM. |
| 2. | Check that the alignment of the TARGET |
|
| and NULL is correct. If not, see the |
|
| Adjustments section. |
| 3. | Check for a light leak: |
|
| • Install a different LAMP MODULE |
|
| ASSEMBLY. If the FOCUS MOTOR |
|
| stops operating continually, install a |
|
| new LAMP MODULE ASSEMBLY. |
| 4. | Check that the voltages across the |
|
| PHOTOCELL are correct. The voltage from |
|
| 1 to 2 is 14.5 V ac. The voltage from 2 to 3 |
|
| is 14.5 V ac. The voltage from 1 to 3 is 29 |
|
| V ac. |
| 5. | Check that the PHOTOCELL HOUSING |
|
| has 2 FILTERS. |
| 6. | Install a new PHOTOCELL. |
| 7. | Check the components on the CIRCUIT |
|
| BOARD for damage. |
|
|
|
AUTO FOCUS MOTOR operates continually in | 1. | Check that the wires of the AUTO FOCUS |
forward only or reverse only and does not |
| MOTOR are in the correct position; the blue |
operate (stops) in the null position. |
| wire goes to the mark on the AUTO FOCUS |
|
| MOTOR. |
|
| |
AUTO FOCUS adjusts after REMOTE use | 1. Do the adjustment for the CLAMP LEVER | |
|
| ASSEMBLY. |
|
|
|
53 |