(4)Paper misfeed in the paper feed-in section of the Second paper cassette(Tray2) 2300 DL & 2350 only

<Detection timing>

Category

Details

 

 

Paper misfeed detected in

If the end of the paper does not interrupt the synchronizing roller sen-

sor (PC2) when a set amount of time has passed after the 2nd drawer

the paper feed-in section

take-up solenoid (SL7) is activated

 

 

 

Remaining paper detected

If the synchronizing roller sensor (PC2) is interrupted when the

in the Second paper cas-

machine is turned on, doors and covers are opened, then closed, and

sette

paper misfeeds and malfunctions are corrected

 

 

<Remedy>

Electrical components for detection of the paper misfeed

2nd drawer take-up solenoid (SL7) Synchronizing roller sensor (PC2)

2nd drawer control board (PWB-A)

 

 

Reference

WARNING DIAGRAM

Step

Remedy

 

 

page

Control signal

Location(electrical com-

 

 

ponent)

 

 

 

 

 

 

 

 

 

1

Perform initial check proce-

152

-

-

dures.

 

 

 

 

 

 

 

 

 

2

Check PC2 operation.

149

PC2_ON

5-D

 

 

 

 

 

4

Check SL7 operation.

150

SL7_REM

7-F

 

 

 

 

 

5

Replace PWB-A.

-

-

-

 

 

 

 

 

(5)Paper misfeed in the transport section, turnover section or storage section of

the duplex unit

<Detection timing>

Category

Details

 

 

Paper misfeed detected in the

If the paper does not interrupt the duplex unit transport sensor (PC17)

turnover, storage or transport

when a set amount of time has passed

section

 

 

 

Remaining paper detected in

If the duplex unit transport sensor (PC17) is interrupted when the

machine is turned on, doors and covers are opened, then closed, and

the transport section

paper misfeeds and malfunctions are corrected

 

 

 

<Remedy>

 

Electrical components for detection of the paper misfeed

Duplex unit transport sensor (PC17)

 

 

Duplex unit control board (PWB-A)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reference

 

WARNING DIAGRAM

Step

Remedy

 

 

 

page

 

Control signal

Location(electrical com-

 

 

 

ponent)

 

 

 

 

 

 

 

 

 

 

 

1

Perform initial check proce-

152

 

-

-

dures.

 

 

 

 

 

 

 

 

 

 

 

 

2

Check PC17 operation.

149

 

PC17_ON

7-C

 

 

 

 

 

 

157