•The temperature control as detailed below is provided by means of the Fusing Roller Heater Lamp (H1) and the Fusing Pressure Roller Heater Lamp (H2).
•The surface temperature of the Fusing Roller is converted by the Thermistor (TH1) to a corresponding electrical signal.
1.
•The temperature during the
•When the temperature of the Fusing Roller reaches this set temperature, both the Fusing Roller Heater Lamp (H1) and the Fusing Pressure Roller Heater Lamp (H2) are turned OFF.
2. Temperature Control in Standby State
• The temperature in the standby state is set at 171°.
3.Temperature Control during Printing (monochrome printing)
• The temperature during printing is set as follows.
| Plain paper | Thick paper | OHP transparen- | Envelopes | Small size* | |
| postcards | cies | ||||
|
|
|
| |||
|
|
|
|
|
| |
Set tempera- | 157° | 157° | 157° | 166° | 152° | |
ture | ||||||
|
|
|
|
| ||
|
|
|
|
|
|
✽
4.Temperature Control during Printing (color printing)
• The temperature during printing is set as follows.
| Plain paper | Thick paper | OHP transparen- | Envelopes | Small size* |
| postcards | cies | |||
|
|
|
| ||
|
|
|
|
|
|
Set temperature | 174° | 174° | 166° | 166° | 169° |
|
|
|
|
|
|
✽
180 | During Printing |
In Standby | |
170 | Plain paper (color) |
|
160
Plain paper (mono- chrome)
4131M061AA | |
180 sec. |
|
70