(4)Replacement of the Fusing Unit

1.Remove the Top Front Cover.

2.Remove the Top Cover.

3.Open the Right-side Door.

4. Remove two screws and the Fusing Unit Cover.

4131D032AA

 

5.

Unplug the connector from the Power Unit and

 

remove the harness from the cord holder.

6.

Remove the Fusing Unit from the machine (two

 

screws and two connectors).

7.

To reinstall the Fusing Unit, reverse the order of

 

removal.

8.

Select functions as follows: Service -> Service/

 

Service Person -> Reset Counter/Fuser Unit.

4131D033AA

Then, clear the counter.

 