(13)FATAL ERROR CODE 1AH / SERVICE CALL 1A FUSER UNIT: Incorrect fusing roller high temperature
(14)FATAL ERROR CODE 1BH / SERVICE CALL 1B FUSER UNIT: Disconnection at thermistor
<Remedy>
Electrical components for detection of the malfunction
Thermistor (TH1) | Master board | |
Controller control board | ||
| ||
|
|
|
|
|
| WARNING DIAGRAM | |
Step | Check | Result | Remedy |
|
|
Control | Location(electrical | ||||
|
|
|
| signal | component) |
|
|
|
|
|
|
|
|
| Clean TH1. |
|
|
|
| YES |
|
|
|
| Is there a short circuit at TH1? | Replace the fusing |
|
| |
1 | (between |
| unit. | HEATER | |
| the thermistor) | NO | Replace PU. |
|
|
|
|
|
|
| |
|
| Replace |
|
| |
|
|
|
|
| |
|
|
|
|
|
|
(15)FATAL ERROR CODE 21H / SERVICE CALL 21 TRANS DET SENS: Malfunction of the OHP detecting sensor
<Remedy>
Electrical components for detection of the malfunction
OHP detecting sensor (PC3A) |
| Master board |
|
| ||
| Controller control board | |||||
|
|
| ||||
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Reference | WARNING DIAGRAM |
| ||
Step | Remedy |
|
|
| ||
page | Control signal | Location(electrical |
| |||
|
| component) |
| |||
|
|
|
|
|
| |
|
|
|
|
|
| |
1 | Check PC3A operation. | PC3_REM |
| |||
|
|
|
|
|
| |
2 | Replace | - | - | - |
| |
|
|
|
|
|
| |
3 | Replace | - | - | - |
| |
|
|
|
|
|
|
|
(16)FATAL ERROR CODE 29H / SERVICE CALL 29 MEM MALF COUNTER: Malfunc- tion of the EEPROM (memory counter error)
(17)FATAL ERROR CODE 2AH / SERVICE CALL 2A MEM MALF DATA: Malfunction of the EEPROM (memory data error)
(18)FATAL ERROR CODE 2BH / SERVICE CALL 2B MEM MALF ACCESS: Malfunc- tion of the EEPROM (memory access error)
(19)FATAL ERROR CODE 2CH: Malfunction of the EEPROM (memory recognition error)
<Remedy>
| Electrical components for detection of the malfunction |
EEPROM | Master board |
165