•If the problem cannot be corrected by the user, a service code is displayed.
(1)FATAL ERROR CODE 04H / SERVICE CALL 04 ENGINE BOARD: Malfunction of the master board
<Remedy>
Components for display of the warning
Master board
|
| Reference | WARNING DIAGRAM | ||
Step | Remedy |
| Location (electrical | ||
Page | Control signal | ||||
|
| component) | |||
|
|
|
| ||
|
|
|
|
| |
1 | Replace | - | - | - |
(2)FATAL ERROR CODE 05H / SERVICE CALL 05 FLASH ROM: Malfunction of the FLASH ROM during initialization
<Remedy>
Components for display of the warning
Controller control board
|
| Reference | WARNING DIAGRAM | ||
Step | Remedy |
| Location (electrical | ||
Page | Control signal | ||||
|
| component) | |||
|
|
|
| ||
|
|
|
|
| |
1 | Turn the printer off and on | - | - | - | |
again. | |||||
|
|
|
| ||
|
|
|
|
| |
2 | Reload system code. | - | - | - | |
3 | Replace | - | - | - | |
| |||||
|
|
|
|
|
(3)FATAL ERROR CODE 08H / SERVICE CALL 08 MAIN MOTOR: Malfunction of the
main motor
<Remedy>
| Components for display of the warning |
| ||||
Main motor (M1) |
| Master board |
| |||
|
|
| Power Unit (PU) |
| ||
|
|
| Controller control board | |||
|
|
|
|
|
| |
|
|
|
|
|
| |
|
| Reference | WARNING DIAGRAM | |||
Step | Remedy |
| Location (electrical | |||
Page | Control signal | |||||
|
| component) | ||||
|
|
|
|
| ||
1 | Check M1 operation. | 151 | M1_REM | |||
2 | Replace PU. | - |
| - | - | |
3 | Replace | - |
| - | - | |
4 | Replace | - |
| - | - |
(4)FATAL ERROR CODE 0BH / SERVICE CALL 0B XFER FAN: Malfunction of the
ventilation fan motor
<Remedy>
| Components for display of the warning |
| ||||
Ventilation fan motor (M6) |
| Master board |
| |||
|
|
| Power Unit (PU) |
| ||
|
|
| Controller control board | |||
|
|
|
|
|
| |
|
| Reference | WARNING DIAGRAM | |||
Step | Remedy |
| Location (electrical | |||
Page | Control signal | |||||
|
| component) | ||||
|
|
|
|
| ||
1 | Check M6 operation. | 151 | M6_REM | |||
2 | Replace PU. | - |
| - | - | |
3 | Replace | - |
| - | - |
161