3-1. Malfunction detection timing and remedies

If the problem cannot be corrected by the user, a service code is displayed.

(1)FATAL ERROR CODE 04H / SERVICE CALL 04 ENGINE BOARD: Malfunction of the master board

<Remedy>

Components for display of the warning

Master board (PWB-A)

 

 

Reference

WARNING DIAGRAM

Step

Remedy

 

Location (electrical

Page

Control signal

 

 

component)

 

 

 

 

 

 

 

 

 

1

Replace PWB-A.

-

-

-

(2)FATAL ERROR CODE 05H / SERVICE CALL 05 FLASH ROM: Malfunction of the FLASH ROM during initialization

<Remedy>

Components for display of the warning

Controller control board (PWB-P)

 

 

Reference

WARNING DIAGRAM

Step

Remedy

 

Location (electrical

Page

Control signal

 

 

component)

 

 

 

 

 

 

 

 

 

1

Turn the printer off and on

-

-

-

again.

 

 

 

 

 

 

 

 

 

2

Reload system code.

-

-

-

3

Replace PWB-P.

-

-

-

 

 

 

 

 

 

(3)FATAL ERROR CODE 08H / SERVICE CALL 08 MAIN MOTOR: Malfunction of the

main motor

<Remedy>

 

Components for display of the warning

 

Main motor (M1)

 

Master board (PWB-A)

 

 

 

 

Power Unit (PU)

 

 

 

 

Controller control board (PWB-P)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Reference

WARNING DIAGRAM

Step

Remedy

 

Location (electrical

Page

Control signal

 

 

component)

 

 

 

 

 

1

Check M1 operation.

151

M1_REM

5-A

2

Replace PU.

-

 

-

-

3

Replace PWB-A.

-

 

-

-

4

Replace PWB-P.

-

 

-

-

(4)FATAL ERROR CODE 0BH / SERVICE CALL 0B XFER FAN: Malfunction of the

ventilation fan motor

<Remedy>

 

Components for display of the warning

 

Ventilation fan motor (M6)

 

Master board (PWB-A)

 

 

 

 

Power Unit (PU)

 

 

 

 

Controller control board (PWB-P)

 

 

 

 

 

 

 

 

Reference

WARNING DIAGRAM

Step

Remedy

 

Location (electrical

Page

Control signal

 

 

component)

 

 

 

 

 

1

Check M6 operation.

151

M6_REM

3-E

2

Replace PU.

-

 

-

-

3

Replace PWB-A.

-

 

-

-

161