Safety regulations (continued)

Supply unit

Always unplug the supply unit from the power supply:

When installing and disassembling the lamp housing

Before opening the lamp housing

When replacing the high-pressure mercury lamp and other parts, such as the heat-ab- sorbing filter or the collector

during maintenance work on the supply unit.

Lamp housing

Never open the lamp housing while the lamp is switched on. Risk of explosion, UV exposure, blinding!

Before opening the lamp housing, allow it to cool off for at least 15 minutes. Danger of explosion!

Never cover the air duct on the lamp hous- ing. Danger of fire!

Mercury lamp

Follow the user manual and safety instruc- tions provided by the lamp manufacturer, and, in particular, the section on how to proceed if a lamp breaks and releases mercury.

For transport, remove the mercury lamp, transport it in its original packaging and protect moving parts in the lamp housing using the transport anchors.

To minimize the risk of explosion, replace a discoloured mercury lamp promptly when it has reached the end of its rated life (follow the manufacturer's specifications and the minute meter on the supply unit).

Leica Microsystems assumes no liability for damage caused by exploding, incor- rectly installed or improperly used mercury lamps.