24xx

 

FRU/Symptom

Action

 

 

 

4

If the prior

The following may cause undefined or

 

suggestions have

intermittent failures:

 

not corrected the

1.Loose connector pins that fail to contact.

 

problem.

 

Check the following:

 

 

 

 

• Reconnect the connectors of all FRUs and

 

 

 

printer interface cables.

 

 

• Check the continuity of the line cord.

 

 

2.Electrical noise. Check the following:

 

 

Power supply ground.

 

 

Printer frame ground.

 

 

• Printer interface cable is grounded or

 

 

 

shielded.

 

 

3.Undefined data in user applications. Check

 

 

the baud rate at the controller. Check that the

 

 

printer interface cable matches the printer.

 

 

 

5

Problem occurs

Perform the Hex Trace Print (hexadecimal

 

only in specific

printing) by the following procedure and check

 

user applications.

the data streams. Go to “Hex Trace Mode” on

 

 

page 3-4.

 

 

1. Turn the printer off.

 

 

2. Press and hold Tractor and turn the printer

 

 

on.

 

 

3. Have the user print the failing job.

 

 

4. To stop printing, turn the power off.

 

 

If the failure still occurs, replace the logic

 

 

board. Be sure to reset the bidirectional print

 

 

adjustment. See “Bidirectional Print

 

 

Adjustment” on page 4-4.

 

 

 

 

2-20Service Manual

Page 38
Image 38
Lexmark 24XX-100 manual Adjustment. See Bidirectional Print