Power-On Self Test (POST)

The following tests are automatically performed when the printer is turned on.

LEDs Test - Checks operation of LEDs on the operator panel. The LEDs turn on and off after the printer is turned on, then all LEDs turn on for a few seconds.

RAM Test - Checks that the CPU can write/read the RAM.

Font ROM/Microcode Sum Test - Checks that the ROM data is correct.

Timer/Interrupt Controller Test - Checks that this function works.

NVRAM Test - Checks that the NVRAM data is correct.

Switch Scan Test - Checks the buttons on operator panel.

Carrier Initialization - Carrier moves to the left to activate the home position sensor, then moves to the first print position.

Feed Initialization - Form feed motor rotates forward and then backward.

If any errors occur during the POST tests, a combination of blinking LEDs indicates which test failed. See “Start” on page 2-1.