Siemens 810T manual Alarm numbers and groups/delete alarms, NC alarms

Models: 810T

1 312
Download 312 pages 8.21 Kb
Page 245
Image 245

4 Monitoring Functions

09.91

4.4 Alarm numbers and groups/delete alarms

4.4Alarm numbers and groups/delete alarms

The alarms are divided into 7 alarm groups (5 NC and 2 PLC alarm groups)

NC alarms:

·

POWER ON alarms

 

·

RS232C (V.24) alarms

 

· RESET alarms/axis-specific

 

· RESET alarms/general

 

·

ERASE alarms

PLC alarms: · PLC error messages

·PLC operational messages

Alarm number

Alarm group

Alarm cleared by ...

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

....

15

POWER ON alarms

Switching on

 

 

 

 

 

 

 

 

 

40

....99, 132* 2)

the control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

16

...

39

RS232C

1. Calling the softkey menu

 

 

 

 

 

including the ºDATA IN-

 

 

 

 

 

(V.24) alarms

 

 

 

 

 

OUTº function1)

 

 

 

 

 

 

2. Operating ºDATA IN-

 

 

 

 

 

 

OUTº softkey

 

 

 

 

 

 

3. Operating ºSTOPº

 

 

 

 

 

 

softkey

 

 

 

 

 

 

 

 

 

 

 

 

100

*

....196 2)

RESET alarms/axis-specific

Operating the

 

 

 

*

 

RESET key

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1320, 1321, 1322, 1323,

RESET alarms/axis-specific

Switching on

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1324

 

 

the control

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

2000

.... 2999

RESET alarms/general

Operating the

 

 

 

 

 

 

RESET key

 

 

 

 

 

 

 

 

 

3000

.... 3201

ERASE alarms

Operating the

 

 

 

 

 

 

acknowledge key

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6000

.... 6163

PLC fault messages

Operating the

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

acknowledge key

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

7000

.... 7023

PLC operator messages

The messages are reset

 

 

 

 

 

 

automatically by the PLC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Tabular overview with assignment of alarm no. and clear function

_______

1)Explanatory notes:

The ºDATA IN-OUTºfunction can be called in the following operating modes:

AUTOMATIC

/ JOG / REFPOINT / INC1 ........ INC10 000 / PRESET

2 ) The asterisk º

* º stands for : º0º = axis 1, º1º = axis 2, º2º = axis 3, º3º = axis 4, º4º = axis 5.

4-4

© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02

 

SINUMERIK 810T, GA3 (BN)

Page 245
Image 245
Siemens 810T manual Alarm numbers and groups/delete alarms, NC alarms, Alarm number Alarm group Alarm cleared by