01.93 4 Monitoring Functions
4.6 Listing of the alarms/alarm description
Alarm No.
Alarm Text:
228*
”Option M19 missing”
Alarm No.
Alarm Text:
M19 S... was programmed in the part program although this function is
not implemented in the control.
Check program
Check NC MD
Upgrade with option E42
Alarm No.
Alarm Text:
3000
”General program error”
Reason:
Remedy:
In one block of the program, a general, not precisely definable,
programming error was made.
Example: An axis was programmed that is not present on the
machine
An incorrect interpolation parameter was programmed
”Axis duplication” option is active and D number in the part program
> 49.
Check the faulty block in ”Correction block”.
If possible, the cursor is positioned in front of the word containing
the error. The number of the block containing the error is displayed
in the alarm line after the alarm No.
Change part program
Alarm No.
Alarm Text:
3001
”Geometry parameters > 5”
Reason:
Remedy:
More than 5 geometry parameters, such as axes, interpolation
parameters, radii, angles have been programmed in a block.
As for alarm 3000
Alarm No.
Alarm Text:
3002
”Polar / radius error”
Reason:
Remedy:
In a block with polar/radius programming:
no angle
no radius
no coordinates for the centre point have been programmed
As for alarm 3000
Alarm No.
Alarm Text:
3003
”Invalid address”
Reason:
Effect:
Remedy:
Axis duplication active and axes of tool system 2 programmed in the
part program.
An address has been programmed that is not defined in machine
data.
NC START inhibited.
Change part program.
© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02 4-25
SINUMERIK 810T, GA3 (BN)