Siemens manual Sinumerik 810T, GA3 BN

Models: 810T

1 312
Download 312 pages 8.21 Kb
Page 252
Image 252

4 Monitoring Functions

09.91

4.6 Listing of the alarms/alarm description

 

Alarm No.

32

 

 

AlarmText:

ºData format error R232C (V.24)º

 

 

Reason:

± The permissible number of decades after an address is not correct

 

±

The decimal point occurs in the wrong place

 

±

The part programs or subroutines are not defined or completed

 

 

correctly (check heading!)

 

±

The NC is waiting for an º=º character, which is not defined in EIA

 

 

code.

Effect:

± Data transfer is interrupted

 

±

The last block is not stored

Remedy:

Check the data to be read in.

 

 

Alarm No.

33

 

 

Alarm Text:

ºDifferent programs same no. R232C (V.24)º

 

 

Reason:

The stored program and the program being read in, have the same

 

program number, but are not identical.

 

With block transfer: Program read in not identical with selected

 

program.

Effect:

No data are stored

Remedy:

Either delete or ºRENAMEº the old program

 

With block transfer: Enter correct program number in Automatic basic

 

display.

Explanation:

If a new program is read in which has the same program number as

 

one already stored, both programs are compared and alarm 33 is

 

displayed.

 

With block transfer: The received program number is compared with

 

the program number specified in the Automatic basic display. If the

 

program numbers differ from each other Alarm 33 is triggered.

 

 

Alarm No.

34

 

 

Alarm Text:

ºOperator error R232C (V.24)º

 

 

Reason:

Data transfer was started on the NC, but the PLC gave a second Start

 

signal.

Effect:

No data are read in

Remedy:

Stop data input, and restart

 

 

Alarm No.

35

 

 

Alarm Text:

ºReader error R232C (V.24)º

 

 

Reason:

Error message from Siemens tape reader

Effect:

± Data transfer is interrupted

 

±

The last block is not stored

Remedy:

±

Restart data transfer

 

± If the fault reoccurs, call Service

 

 

 

4-10

© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02

SINUMERIK 810T, GA3 (BN)

Page 252
Image 252
Siemens manual Sinumerik 810T, GA3 BN