11.90

3 Operating Sequences

3.1.13 Program management

3.1.13.2 Protection of subroutines (cycle lock)

You can protect subroutines from unauthorised output or inadvertent deletion by locking them:

Sequence of operation

PART

 

DIREC-

 

SUB-

PROGRAM

 

TORY

 

ROUT.

 

 

 

 

 

 

 

 

 

 

 

Operate the ºPART PROGRAMº,

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ºDIRECTORYº and ºSUBROUTINEº softkeys one after

 

 

 

 

 

 

 

 

 

 

 

the other in any of the operating modes:

 

 

 

 

 

 

 

 

 

 

 

PRESET / JOG / AUTOMATIC /

 

 

 

 

 

 

 

 

 

 

 

INC1... INC10 000 / REFPOINT

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

3

L

...

Using the keyboard enter ºLº for the subroutine, and the number of the desired subroutine.

· · ·

LOCK

Now operate the ºLOCKº softkey.

The protected subroutine is entered in the cycle list.

Cycles are protected subroutines.

© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02

3-59

SINUMERIK 810T, GA3 (BN)

Page 161
Image 161
Siemens 810T manual Protection of subroutines cycle lock, Part Direc SUB Program Tory Rout, Preset / JOG / Automatic, Lock