09.91

3 Operating Sequences

3.2.3 Influencing ºAUTOMATICº operation

DRY

YES-NO

You select, for example, the ºDRY RUN FEEDRATEº softkey.

Display:

Dry run feedrate

All blocks in which a feedrate is programmed (G01, G02, G03, G33, G34, G35) will now be traversed at the feedrate value entered into the ºDry run feedrateº setting data, instead of the programmed feedrate.

The dry run feedrate then applies to ºFeed per revolutionº G95, and the feedrates for threading (G33,G34,G35).

OPT.

STOP

YES-NO

You select, for example, the ºOPTIONAL STOPº softkey function

Display:

Optional stop

YES

When an ºM01º is present in the part program, the program is stopped.

When the softkey function is marked with ºNOº, ºM01º is ignored.

OVERR.

YES-NO

You select, for example, the ºRAPID OVERRIDEº softkey function.

Display:

Rapid override

YES

This signal requires that there is a common feedrate/rapid override switch. If the softkey function is set to ºNOº, this override switch is only active with ºfeedrateº. If the softkey function is set to ºYESº, the override set with this override switch is also effective for rapid traverse.

© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02

3-95

SINUMERIK 810T, GA3 (BN)

Page 198
Image 198
Siemens 810T manual Dry Yes-No, OPT Stop YES-NO, Overr YES-NO