Siemens 810T manual Stop Edit Start OPS, End

Models: 810T

1 312
Download 312 pages 8.21 Kb
Page 217
Image 217

3 Operating Sequences

09.91

3.2.3 Influencing ºAUTOMATICº operation

Sequence of operation

STOP EDIT

0

S

START OPS

You stop program sequencing manually by operating the "STOP EDIT" softkey.

End:

Program sequencing comes to a regular end as soon as the program number 0000 is reached the first time during processing the program sequence list.

Enter consecutive number 0, if No. 0 exists in the list and press the search key.

Operate the "START OPS" softkey.

OPS operation is terminated (program number 0000 is reached).

As opposed to "Interruption", "End" results in the internal OPS management being reset to its defined starting state. In the case of an interruption, internal flags and pointers are preserved as they were at the moment of interruption.

Note:

If "STOP EDIT" is pressed while programs are being transferred (indicated by the "DIO" screen display), it may happen that the last program loaded is incomplete in the NC memory! Unless the "OPS mode" display is left, this has no consequences at all.

In the case of a return jump to the "Note: "OPS mode" display this can result in an error message ("Different programs same No. (RS232C (V.24))") if the incompletely transferred file is once again called from there.

For further details, please refer to the documents on the DSG-2S disk drive.

3-112

© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02

SINUMERIK 810T, GA3 (BN)

Page 217
Image 217
Siemens 810T manual Stop Edit Start OPS, End