4 Monitoring Functions

01.93

4.6 Listing of the alarms/alarm description

 

Alarm No.

2153

 

 

Alarm Text:

ºControl loop spindle HWº

 

 

Reason:

As for alarm 132*

Effect:

± Inhibiting of NC START

 

±

Operation is brought to a defined standstill

Remedy:

As for alarm 132*

 

 

Alarm No.

2154

 

 

Alarm Text:

ºSpindle measuring system dirtyº

 

 

Reason:

On measuring systems with a contamination signal, the measuring

 

system has signalled a fault to the NC

Effect:

Inhibiting of NC START

Remedy:

Check the measuring system

 

 

Alarm No.

2155

 

 

Alarm Text:

ºOption M19 not availableº

 

 

Reason:

ºM19 S ...º has been programmed, although this function is not

 

present

Effect:

Inhibiting of NC START

Remedy:

±

Correct program

 

±

Retrofit option ºM19º

 

 

Alarm No.

2160

 

 

Alarm Text:

ºScale factor not allowedº

 

 

Remedy:

Modify scale factor

 

 

Alarm No.

2161

 

 

Alarm Text:

ºScale change not allowedº

 

 

Remedy:

Correct scale modification

 

 

Alarm No.

2171

 

 

Alarm Text:

ºApproach not possibleº

 

 

Remedy:

Correct approach block

 

 

Alarm No.

2172

 

 

Alarm Text:

ºRetract not possibleº

 

 

Remedy:

Correct retraction block

 

 

Alarm No.

2173

 

 

Alarm Text:

ºWrong approach/retract planeº

 

 

Remedy:

Correct approach/retraction plane

 

 

Alarm-Nr.

2183

 

 

Alarm-Text:

ºAxis is not a rotary axisº

 

 

Reason:

The axis must be declared a rotary axis in MD 564*, bit 5.

Effect:

NC Start and NC READY 2 disabled.

Remedy:

Set MD 564*, bit 5=1.

 

 

 

4-22

 

© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02

SINUMERIK 810T, GA3 (BN)

Page 265
Image 265
Siemens 810T manual 2153, 2154, 2155, 2160, 2161, 2171, 2172, 2173, 2183