4 Monitoring Functions

4.6

Listing of the alarms/alarm description

Alarm No.

3042

 

 

 

Alarm Text:

ºDisplay description errorº

{serious error}

 

 

Reason:

An error has been found in the display description which cannot be

 

exactly defined; e. g. a non-existent field has been programmed.

Remedy:

Check the display with the workstation

Explanation:

Only with additional programming via WS 800

 

 

 

Alarm No.

3043

 

 

 

Alarm Text:

ºDisplay description errorº

{non serious error}

 

 

 

Reason:

As for alarm 3042

 

Remedy:

As for alarm 3042

 

Explanation:

As for alarm 3042

 

 

 

 

Alarm No.

3046

 

 

 

Alarm Text:

ºVariable errorº

 

 

 

Reason:

A variable has been selected that cannot be displayed in the control.

Remedy:

Check display with workstation

 

Explanation:

Only with additional programming via WS800

 

 

 

Alarm No.

3048

 

 

 

Alarm Text:

ºWrong workpiece definitionº

 

 

 

Reason:

Minimum and maximum workpiece definition values have been

 

interchanged.

 

Remedy:

Check the workpiece definition for valid values

 

 

 

Alarm No.

3049

 

 

 

Alarm Text:

ºWrong simulation area!º

 

 

 

Reason:

Incorrect or no values given for the definition of the simulation area

Remedy:

± Check the values for the simulation area (all planes)

 

± A new start of simulation is possible after RESET and operation of

 

the ºACKNOWLEDGE ALARMº key

 

 

 

Alarm No.

3050

 

 

 

Alarm Text:

ºIncorrect inputº

 

 

 

Reason:

Incorrect/undefined simulation data

 

 

 

Alarm No.

3063

 

 

 

Alarm Text:

ºData block not availableº

 

 

 

Explanation:

A DB No. was selected in PLC STATUS which is not available.

Remedy:

Select or create the correct data block.

 

 

 