4 Monitoring Functions

4.6

Listing of the alarms/alarm description

Alarm No.

3020

 

 

Alarm Text:

ºOption not availableº

 

 

Reason:

A function has been programmed which is not implemented in the

 

system.

Remedy:

± As for alarm 3000

 

±

Retrofit option

 

 

Alarm No.

3021

 

 

Alarm Text:

ºCRC/TNRC contour errorº

 

 

Reason:

The compensation calculation results in a traversing movement which

 

is in the opposite direction to the movement programmed.

Remedy:

Check the program.

 

 

Alarm No.

3024

 

 

Alarm Text:

ºDisplay description not availableº

 

 

Reason:

A jump has been made with a programmed softkey to a display which

 

is not present in the UMS memory.

Remedy:

± Check graphic display number

 

±

Check softkey function

Explanation:

Only with additional programming developed in WS 800.

 

 

Alarm No.

3025

 

 

Alarm Text:

ºDisplay description errorº

 

 

Reason:

± A display with graphic elements has been programmed, without the

 

 

graphic option fitted in the control.

 

±

The selected display has too many variables or fields.

 

±

A type of display has been programmed that is not valid for the

 

 

control.

Remedy:

± Check the display using the workstation

 

±

Retrofit graphics option

Explanation:

Only with additional programming developed in WS 800

 

 

Alarm No.

3026

 

 

Alarm Text:

ºGraphics / text too voluminousº

 

 

Reason:

± Projecting error in selected display

 

±

Sum of the display and text elements too large

Remedy:

± Check display with workstation

 

± Distribute the contents into two displays

Explanation:

Only with additional programming developed in WS 800

 

 

Alarm No.

3027

 

 

Alarm Text:

ºGraphics command too voluminousº

 

 

Reason:

The total of graphics commands in the display selected is too great

Remedy:

As for alarm 3026

Explanation:

± This alarm triggers alarm 3026

 

±

Only with additional programming via WS 800

 

 

 