11.90

4 Monitoring Functions

4.6

Listing of the alarms/alarm description

Alarm No.

156*

 

 

Alarm Text:

ºSet speed too highº

 

 

Reason:

Within the control, a higher set speed was output than the value set in

 

machine data 264*.

Effect:

The motor cannot follow the speed command value

± Inhibiting of NC START

 

±

Operation is brought to a defined stop

Remedy:

±

Follow-up operation

Report the problem to Service

 

 

Alarm No.

160*

 

 

Alarm Text:

ºDrift too highº

 

 

Reason:

The drift to be corrected by the NC is too high

Effect:

± Inhibiting of NC START

 

±

The green ºPosition not yet reached ºLED lights up

 

±

No traverse movement possible

Remedy:

Execute drift compensation (Service)

 

 

Alarm No.

168*

 

 

Alarm Text:

ºServo enable, trav. axisº

 

 

Reason:

The axis-specific servo enable signal was removed by the PLC user

Effect:

program during traversing.

± Inhibiting of NC START

 

±

Operation is brought to a defined stop

Remedy:

±

Follow-up operation

Report the problem to Service

 

 

 

Alarm No.

172* / 176*

 

 

Alarm Text:

º+* / ±* Working area limitº

 

 

Reason:

The set working area limits have been reached

Effect:

Inhibiting of NC START

Remedy:

±

Check the program

Explanation:

±

Check the working area limits in setting data.

Working area limits in ºJOGº mode are set in a machine data

 

 

 

Alarm No.

180*

 

 

Alarm Text:

ºAxis in several channelsº

 

 

Reason:

With two programs running simultaneously in different channels, one

 

axis was programmed in both programs (channels), causing a

 

traversing movement for the related axis to be output for both

 

programs.

Effect:

Inhibiting of NC START

Remedy:

Check both programs

 

 

 

_______

º*º stands for : º0º = axis 1, º1º = axis 2, º2º = axis 3, º3º = axis 4, º4º = axis 5

© Siemens AG 1990 All Rights Reserved 6ZB5 410-0EP02

4-13

SINUMERIK 810T, GA3 (BN)

 

Page 255
Image 255
Siemens 810T manual 156, 160, 168, 172, 180